Mercurial > hg > orthanc
view OrthancFramework/Sources/Logging.h @ 5858:66fd63b8601e find-refactoring
StorageAccessOnFind: cont
author | Alain Mazy <am@orthanc.team> |
---|---|
date | Mon, 04 Nov 2024 22:34:14 +0100 |
parents | f7adfb22e20e |
children |
line wrap: on
line source
/** * Orthanc - A Lightweight, RESTful DICOM Store * Copyright (C) 2012-2016 Sebastien Jodogne, Medical Physics * Department, University Hospital of Liege, Belgium * Copyright (C) 2017-2023 Osimis S.A., Belgium * Copyright (C) 2024-2024 Orthanc Team SRL, Belgium * Copyright (C) 2021-2024 Sebastien Jodogne, ICTEAM UCLouvain, Belgium * * This program is free software: you can redistribute it and/or * modify it under the terms of the GNU Lesser General Public License * as published by the Free Software Foundation, either version 3 of * the License, or (at your option) any later version. * * This program is distributed in the hope that it will be useful, but * WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU * Lesser General Public License for more details. * * You should have received a copy of the GNU Lesser General Public * License along with this program. If not, see * <http://www.gnu.org/licenses/>. **/ #pragma once // To have ORTHANC_ENABLE_LOGGING defined if using the shared library #include "OrthancFramework.h" #include "Compatibility.h" #include <iostream> #include <stdint.h> #if !defined(ORTHANC_ENABLE_LOGGING) # error The macro ORTHANC_ENABLE_LOGGING must be defined #endif #if !defined(ORTHANC_ENABLE_LOGGING_STDIO) # if ORTHANC_ENABLE_LOGGING == 1 # error The macro ORTHANC_ENABLE_LOGGING_STDIO must be defined # else # define ORTHANC_ENABLE_LOGGING_STDIO 0 # endif #endif namespace Orthanc { namespace Logging { // Note: these values must match the ones in OrthancCPlugin.h enum LogLevel { LogLevel_ERROR = 0, LogLevel_WARNING = 1, LogLevel_INFO = 2, LogLevel_TRACE = 3 }; /** * NB: The log level for each category is encoded as a bit * mask. As a consequence, there can be up to 31 log categories * (not 32, as the value GENERIC is reserved for the log commands * that don't fall in a specific category). * Note: these values must match the ones in OrthancCPlugin.h **/ enum LogCategory { LogCategory_GENERIC = (1 << 0), LogCategory_PLUGINS = (1 << 1), LogCategory_HTTP = (1 << 2), LogCategory_SQLITE = (1 << 3), LogCategory_DICOM = (1 << 4), LogCategory_JOBS = (1 << 5), LogCategory_LUA = (1 << 6) }; ORTHANC_PUBLIC const char* EnumerationToString(LogLevel level); ORTHANC_PUBLIC LogLevel StringToLogLevel(const char* level); // "pluginContext" must be of type "OrthancPluginContext" ORTHANC_PUBLIC void InitializePluginContext(void* pluginContext); ORTHANC_PUBLIC void InitializePluginContext(void* pluginContext, const std::string& pluginName); ORTHANC_PUBLIC void Initialize(); ORTHANC_PUBLIC void Finalize(); ORTHANC_PUBLIC void Reset(); ORTHANC_PUBLIC void Flush(); ORTHANC_PUBLIC void SetCurrentThreadName(const std::string& name); ORTHANC_PUBLIC bool HasCurrentThreadName(); ORTHANC_PUBLIC void EnableThreadNames(bool enabled); ORTHANC_PUBLIC void EnableInfoLevel(bool enabled); ORTHANC_PUBLIC void EnableTraceLevel(bool enabled); ORTHANC_PUBLIC bool IsTraceLevelEnabled(); ORTHANC_PUBLIC bool IsInfoLevelEnabled(); ORTHANC_PUBLIC void SetCategoryEnabled(LogLevel level, LogCategory category, bool enabled); ORTHANC_PUBLIC bool IsCategoryEnabled(LogLevel level, LogCategory category); ORTHANC_PUBLIC bool LookupCategory(LogCategory& target, const std::string& category); ORTHANC_PUBLIC unsigned int GetCategoriesCount(); ORTHANC_PUBLIC const char* GetCategoryName(unsigned int i); ORTHANC_PUBLIC const char* GetCategoryName(LogCategory category); ORTHANC_PUBLIC void SetTargetFile(const std::string& path); ORTHANC_PUBLIC void SetTargetFolder(const std::string& path); struct ORTHANC_LOCAL NullStream : public std::ostream { NullStream() : std::ios(0), std::ostream(0) { } template <typename T> std::ostream& operator<< (const T& message) { return *this; } }; } } /** * NB: * - The "VLOG(unused)" macro is for backward compatibility with * Orthanc <= 1.8.0. * - The "CLOG()" macro stands for "category log" (new in Orthanc 1.8.1) **/ #if defined(LOG) # error The macro LOG cannot be defined beforehand #endif #if defined(VLOG) # error The macro VLOG cannot be defined beforehand #endif #if defined(CLOG) # error The macro CLOG cannot be defined beforehand #endif #if ORTHANC_ENABLE_LOGGING != 1 # define LOG(level) ::Orthanc::Logging::NullStream() # define VLOG(unused) ::Orthanc::Logging::NullStream() # define CLOG(level, category) ::Orthanc::Logging::NullStream() # define LOG_FROM_PLUGIN(level, category, pluginName, file, line) ::Orthanc::Logging::NullStream() #else /* ORTHANC_ENABLE_LOGGING == 1 */ #if !defined(__ORTHANC_FILE__) # if defined(_MSC_VER) # pragma message("Warning: Macro __ORTHANC_FILE__ is not defined, this will leak the full path of the source files in the binaries") # else # warning Warning: Macro __ORTHANC_FILE__ is not defined, this will leak the full path of the source files in the binaries # endif # define __ORTHANC_FILE__ __FILE__ #endif # define LOG(level) ::Orthanc::Logging::InternalLogger \ (::Orthanc::Logging::LogLevel_ ## level, \ ::Orthanc::Logging::LogCategory_GENERIC, NULL /* no plugin */, \ __ORTHANC_FILE__, __LINE__) # define VLOG(unused) ::Orthanc::Logging::InternalLogger \ (::Orthanc::Logging::LogLevel_TRACE, \ ::Orthanc::Logging::LogCategory_GENERIC, NULL /* no plugin */, \ __ORTHANC_FILE__, __LINE__) # define CLOG(level, category) ::Orthanc::Logging::InternalLogger \ (::Orthanc::Logging::LogLevel_ ## level, \ ::Orthanc::Logging::LogCategory_ ## category, NULL /* no plugin */, \ __ORTHANC_FILE__, __LINE__) # define LOG_FROM_PLUGIN(level, category, pluginName, file, line) \ ::Orthanc::Logging::InternalLogger(level, category, pluginName, file, line) #endif #if (ORTHANC_ENABLE_LOGGING == 1 && \ ORTHANC_ENABLE_LOGGING_STDIO == 1) // This is notably for WebAssembly #include <boost/lexical_cast.hpp> #include <boost/noncopyable.hpp> #include <sstream> namespace Orthanc { namespace Logging { class ORTHANC_PUBLIC InternalLogger : public boost::noncopyable { private: LogLevel level_; LogCategory category_; std::stringstream messageStream_; public: InternalLogger(LogLevel level, LogCategory category, const char* pluginName /* ignored */, const char* file /* ignored */, int line /* ignored */) : level_(level), category_(category) { } ~InternalLogger(); template <typename T> std::ostream& operator<< (const T& message) { return messageStream_ << boost::lexical_cast<std::string>(message); } }; } } #endif #if (ORTHANC_ENABLE_LOGGING == 1 && \ ORTHANC_ENABLE_LOGGING_STDIO == 0) #include <boost/lexical_cast.hpp> #include <boost/noncopyable.hpp> #include <boost/thread/mutex.hpp> #include <sstream> namespace Orthanc { namespace Logging { class ORTHANC_PUBLIC InternalLogger : public boost::noncopyable { private: boost::mutex::scoped_lock lock_; LogLevel level_; std::unique_ptr<std::stringstream> pluginStream_; std::ostream* stream_; LogCategory category_; const char* file_; uint32_t line_; public: InternalLogger(LogLevel level, LogCategory category, const char* pluginName, const char* file, int line); ~InternalLogger(); template <typename T> std::ostream& operator<< (const T& message) { return (*stream_) << boost::lexical_cast<std::string>(message); } }; /** * Set custom logging streams for the error, warning and info * logs. This function may not be called if a log file or folder * has been set beforehand. All three references must be valid. * * Please ensure the supplied streams remain alive and valid as * long as logging calls are performed. In order to prevent * dangling pointer usage, it is mandatory to call * Orthanc::Logging::Reset() before the stream objects are * destroyed and the references become invalid. * * This function must only be used by unit tests. It is ignored if * InitializePluginContext() was called. **/ ORTHANC_PUBLIC void SetErrorWarnInfoLoggingStreams(std::ostream& errorStream, std::ostream& warningStream, std::ostream& infoStream); } } #endif