Mercurial > hg > orthanc-book
view Sphinx/source/integrations/ginkgo-cadx.rst @ 395:d44f6f93a987
osimis/orthanc doc update
author | Alain Mazy <alain@mazy.be> |
---|---|
date | Tue, 21 Apr 2020 17:03:46 +0200 |
parents | 8f3f79aeb8cc |
children |
line wrap: on
line source
.. _ginkgo-cadx: Ginkgo CADx =========== This section explains how to connect the `Ginkgo CADx viewer <http://ginkgo-cadx.com/en/>`__ to an Orthanc server, both running on the local computer. First, start Orthanc without specifying a configuration file (i.e. using its default configuration). Then, open the settings pannel of Ginkgo CADx: .. image:: ../images/GinkgoCADx1.png :align: center :width: 500px Write down the AET and the DICOM port of Ginkgo CADx (in this case, respectively ``GINKGO_001`` and ``11112``). Then, create a new DICOM node corresponding to Orthanc by clicking on the "*New...*" button, which raises the following dialog box: .. image:: ../images/GinkgoCADx2.png :align: center :width: 400px .. highlight:: json Complete the highlighted fields with the default parameters of Orthanc, as shown in the screenshot. Do not forget to click on the "*Test connection*" button to make sure the :ref:`C-Echo <dicom-echo>` succeeds. Stop Orthanc, create a new :ref:`configuration file <configuration>`, and declare Gingko CADx in the ``DicomModalities`` section, given the parameters you wrote down above:: // The list of the known DICOM modalities "DicomModalities" : { "ginkgo" : [ "GINKGO_001", "localhost", 11112 ] }, Restart Orthanc using this newly created configuration file, and you will be able to do query/retrieve from Gingko CADx through the "*PACS Q/R*" menu.