Mercurial > hg > orthanc-book
view Sphinx/source/faq/query-retrieve.rst @ 0:901e8961f46e
initial commit
author | Sebastien Jodogne <s.jodogne@gmail.com> |
---|---|
date | Fri, 22 Apr 2016 12:57:38 +0200 |
parents | |
children | 8f3f79aeb8cc |
line wrap: on
line source
.. _query-retrieve: Configuring DICOM Query/Retrieve ================================ Starting with release 0.7.0, Orthanc supports DICOM Query/Retrieve (i.e. Orthanc can act as C-Find SCP and C-Move SCP). To configure this feature, follow these instructions: * Get the AET (Application Entity Title), the IP address and the port number of your DICOM client. * Add an entry in the ``DicomModalities`` section of your Orthanc :ref:`configuration file <configuration>` to reflect these settings. * Restart Orthanc with the updated configuration file. * Symmetrically, in your DICOM client, configure an additional DICOM node corresponding to your Orthanc AET (see the ``DicomAet`` parameter of your Orthanc configuration, by default, ORTHANC), IP address et port number (cf. ``DicomPort``, by default 4242). If you encounter configuration problem with query/retrieve, please be sure to read the :ref:`dicom-move` section. .. _ginkgo-cadx: Illustration: Ginkgo CADx ------------------------- This section explains how to connect the `Ginkgo CADx viewer <http://ginkgo-cadx.com/en/>`__ to an Orthanc server, both running on the local computer. First, start Orthanc without specifying a configuration file (i.e. using its default configuration). Then, open the settings pannel of Ginkgo CADx: .. image:: ../images/GinkgoCADx1.png :align: center :width: 500px Write down the AET and the DICOM port of Ginkgo CADx (in this case, respectively ``GINKGO_001`` and ``11112``). Then, create a new DICOM node corresponding to Orthanc by clicking on the "*New...*" button, which raises the following dialog box: .. image:: ../images/GinkgoCADx2.png :align: center :width: 400px .. highlight:: json Complete the highlighted fields with the default parameters of Orthanc, as shown in the screenshot. Do not forget to click on the "*Test connection*" button to make sure the :ref:`C-Echo <dicom-echo>` succeeds. Stop Orthanc, create a new :ref:`configuration file <configuration>`, and declare Gingko CADx in the ``DicomModalities`` section, given the parameters you wrote down above:: // The list of the known DICOM modalities "DicomModalities" : { "ginkgo" : [ "GINKGO_001", "localhost", 11112 ] }, Restart Orthanc using this newly created configuration file, and you will be able to do query/retrieve from Gingko CADx through the "*PACS Q/R*" menu.