Mercurial > hg > orthanc-book
view Sphinx/source/dicom-guide.rst @ 1:1b6f12b8a54b
license in footer
author | Sebastien Jodogne <s.jodogne@gmail.com> |
---|---|
date | Fri, 22 Apr 2016 14:18:42 +0200 |
parents | 901e8961f46e |
children | 6e99967d3503 |
line wrap: on
line source
.. _dicom-guide: Understanding DICOM with Orthanc ================================ .. contents:: This section of the Orthanc Book provides a **gentle, informal, high-level introduction to DICOM**. We will try and map DICOM's own concepts to a modern terminology that should hopefully be more easy to understand for software engineers diving for the first time into DICOM. Once the concepts of this page are understood, interested readers are invited to read a more formal textbook about DICOM, such as the so-called "`Practical introduction and survival guide <http://www.springer.com/us/book/9783642108495>`__", or to read the full `DICOM specification <http://medical.nema.org/medical/dicom/current/output/html/>`__. All the DICOM concepts that are defined in this introduction are illustrated with `Orthanc <http://www.orthanc-server.com/>`__, a lightweight, yet powerful standalone DICOM server for healthcare and medical research. As Orthanc is free and open-source software, it is a good companion to learn DICOM. .. _dicom-format: DICOM file format ----------------- The DICOM standard can be very roughly divided in 2 parts: 1. The part specifying the DICOM **file format**. 2. The part specifying the DICOM **network protocol**. The DICOM file format is the topic of the present section. It is inherently similar to well-known formats such as JPEG, PNG or TIFF. However, besides the so-called "**pixel data**" that encodes the medical image itself, a DICOM file also embeds medical information. .. _dicom-tags: DICOM tags ^^^^^^^^^^ The medical information encoded by a DICOM file is called a **data set** and takes the form of a `key-value associative array <https://en.wikipedia.org/wiki/Associative_array>`__. Each value can itself be a list of data sets (called a **sequence**), leading to a hierarchical data structure that is much like a XML or JSON file. In the DICOM terminology, each key is called a **DICOM tag**. The list of the standard DICOM tags are normalized by an official dictionary, each tag being identified by two 16-bit hexadecimal numbers. For instance, the birth date of a patient is associated with the DICOM tag ``(0x0010, 0x0030)``. Note that it is common to drop the "``0x``" prefix and to simply write ``0010,0030``. For better readability, it is also common to nickname these DICOM tags with a `camel case <https://en.wikipedia.org/wiki/CamelCase>`__ English name (such as "*PatientName*" or "*StudyDescription*"). The standard associates each DICOM tag with a data type (a string, a date, a floating-point number...), that is known as its **value representation**. Here is how :ref:`Orthanc Explorer <orthanc-explorer>` displays the DICOM tags stored in a DICOM file (note that the file contains a sequence identified by the tag ``ProcedureCodeSequence (0x0008, 0x1032)``): .. image:: images/DicomTags.png :align: center :width: 450px | The DICOM file format also specifies the set of DICOM tags that are mandatory or optional for each kind of imaging modality (CT, MR, NM, CBCT, PET...). Such a specification is called a **storage service-object pair** (storage SOP). Mandatory tags are called "*type 1*", mandatory tags that can have a null value are called "*type 2*", and optional tags are called "*type 3*". The DICOM standard also allows vendors to introduce non-standard, **proprietary tags** for their own use. Proprietary tags can be identified by the fact that their first hexadecimal number is odd (e.g. ``(0x0009, 0x0010)``). Obviously, such proprietary tags should be avoided for maximal interoperability. .. _dicom-pixel-data: Pixel data ^^^^^^^^^^ The image itself is associated with the DICOM tag ``PixelData (0x7fe0, 0x0010)``. The content of image can be compressed using many image formats, such as JPEG, `Lossless JPEG <https://en.wikipedia.org/wiki/Lossless_JPEG>`__ or `JPEG 2000 <https://en.wikipedia.org/wiki/JPEG_2000>`__. Obviously, non-destructive (lossless) compression should always be favored to avoid any loss of medical information. Note that a DICOM file can also act as a wrapper around a video encoded using `MPEG-2 <https://en.wikipedia.org/wiki/MPEG-2>`__ or `H.264 <https://en.wikipedia.org/wiki/H.264/MPEG-4_AVC>`__. The image compression algorithm can be identified by inspecting the **transfer syntax** that is associated with the DICOM file in its header. In practice, few imaging devices in hospitals (besides the `PACS <https://en.wikipedia.org/wiki/Picture_archiving_and_communication_system>`__ itself) support image compression. As a consequence, to ensure best portability, the pixel data of most DICOM files circulating in hospitals is **uncompressed**. In other words, the image is encoded as a raw buffer, with a given width, height, pixel type (integer or float), `color depth <https://en.wikipedia.org/wiki/Color_depth>`__ (most often 8, 10, 12 bpp - *bits per pixel*) and photometric interpretation (most often grayscale or RGB). The transfer syntax that is associated with such uncompressed images can either be `little endian <https://fr.wikipedia.org/wiki/Endianness>`__ (the most common case) or big endian. A DICOM image can be **multi-frame**, meaning that it encodes an array of different image frames. This is for instance used to encode uncompressed video sequences, that are often referred to as **cine** or **2D+t** images (e.g. for `ultrasound imaging <https://en.wikipedia.org/wiki/Medical_ultrasound>`__). `As written in its DICOM conformance statement <https://bitbucket.org/sjodogne/orthanc/src/default/Resources/DicomConformanceStatement.txt>`__, the Orthanc software can receive, store and send any kind of DICOM images (i.e. all the standard transfer syntaxes are supported). Furthermore, Orthanc can :ref:`convert most uncompressed images <supported-images>` to PNG images. The `PNG format <https://en.wikipedia.org/wiki/Portable_Network_Graphics>`__ was chosen by Orthanc as it is lossless, is natively supported by many browsers, software or programming frameworks, and is able to encode up to 16bpp integer pixels. This on-the-fly conversion to PNG images is what happens when previewing a DICOM image within :ref:`Orthanc Explorer <orthanc-explorer>`: .. image:: images/PreviewInstance.png :align: center :width: 400px Model of the real world ^^^^^^^^^^^^^^^^^^^^^^^ This concludes our overview of the DICOM file format itself. It is now important to give an overview of the so-called "**DICOM model of the real world**" (`source <http://medical.nema.org/medical/dicom/current/output/html/part04.html#sect_C.6.1.1>`__): .. image:: images/PS3.4_C.6-1.svg :align: center :height: 400px This UML diagram shows that a given **patient** benefits during her life from a set of medical imaging **studies**. Each study is made of a set of **series**. Each series is in turn a set of **instances**, the latter being a synonym for a single DICOM file. In Orthanc's vocabulary, a **DICOM resource** is an umbrella term to talk either about a patient, a study, a series or an instance. Any imaging study can be associated with multiple series of images. This is especially visible with nuclear medicine, as any `PET-CT-scan <https://en.wikipedia.org/wiki/PET-CT>`__ study will contain at least two separate series: the CT series and the PET series. But any kind of imaging study will usually generate a set of separate series. In general, a series can be thought of as either a single 2D image (as in standard `digital radiography <https://en.wikipedia.org/wiki/Digital_radiography>`__), a single 3D volume (as in a `CT-scan <https://en.wikipedia.org/wiki/CT_scan>`__), or a 2D+t cine sequence. But a series might also encode a single PDF report, a `structured report <http://www.dclunie.com/pixelmed/DICOMSR.book.pdf>`__, a 3D+t image (i.e. a temporal sequence of 3D images)... In any case, the actual pixel data of a given series is spread across multiple DICOM instances. This allows to split a single huge image (medical imaging commonly deals with 4GB images) into hundreds of small files of several megabytes, each of which can entirely fit in the computer memory, at the price of a severe redundancy of the medical information that is embedded within these files. For each of these 4 kinds of DICOM resources, the DICOM standard specifies a **module** as a set of DICOM tags that describe these resources. For instance, the DICOM tag *PatientName* is part of the patient module, whereas *SeriesDescription* is part of the series module. Any storage service-object pair (as :ref:`defined above <dicom-tags>`) can be decomposed into a set of modules that make sense for its associated type of modality, and whose conjunction forms encodes all the medical information. According to this model of the real world, the default Web interface of Orthanc allows to browse from the patient level to the instance level. Here is how :ref:`Orthanc Explorer <orthanc-explorer>` displays a series: .. image:: images/RealWorld.png :align: center :width: 450px | On the left side of the interface, an overview of the patient module, the study module and the series module is displayed. On the right side, the multiple instances of the series are accessible. .. _dicom-identifiers: DICOM identifiers ^^^^^^^^^^^^^^^^^ Very importantly, the DICOM standard specifies DICOM tags that allow to index each single DICOM resource: * Patients are indexed with ``PatientID (0x0010, 0x0020)`` (part of the patient module). * Studies are indexed with ``StudyInstanceUID (0x0020, 0x000d)`` (part of the study module). * Series are indexed with ``SeriesInstanceUID (0x0020, 0x000e)`` (part of the series module). * Instances are indexed with ``SOPInstanceUID (0x0008, 0x0018)`` (part of the SOP module). The DICOM standard orders *StudyInstanceUID*, *SeriesInstanceUID* and *SOPInstanceUID* to be `globally unique <https://en.wikipedia.org/wiki/Globally_unique_identifier>`__. In other words, it is mandatory for two different imaging devices to never generate the same identifiers, even if they are manufactured by different vendors. Orthanc exploits this rule to derive its :ref:`own unique identifiers <orthanc-ids>`. Importantly, even if the *PatientID* must be unique inside a given hospital, it is not guaranteed to be globally unique. This means that different patients imaged in different hospitals might share the same *PatientID*. For this reason, you should always browse from the study level (and not from the patient level) as soon as you deal with an application that handles patients from different hospitals. *Note:* The current version of the :ref:`Orthanc Explorer <orthanc-explorer>` interface (1.0.0 at the time of writing) is designed for single-hospital scenarios, and thus does not provide study-level access. But the core engine of Orthanc does support study-level access through its :ref:`REST API <rest>`. Finally, the patient module is not always fully meaningful. This is for instance the case in emergency imaging, where the `radiology information system <https://en.wikipedia.org/wiki/Radiology_information_system>`__ might not have previously encountered the imaged patient. In such a case, an unique ``AccessionNumber (0x0008, 0x0050)`` is associated with the imaging study by the imaging device of the emergency room: The patient module will be injected later on in the PACS once the administrative information is available, as part of a reconciliation process. In any case, the core engine Orthanc keeps an index of all these DICOM identifiers (*PatientID*, *AccessionNumber*, *StudyInstanceUID*, *SeriesInstanceUID* and *SOPInstanceUID*) and is able to quickly maps them to its own :ref:`internal identifiers <orthanc-ids>`. This lookup is implemented by the ``/tools/lookup`` URI of the :ref:`REST API of Orthanc <rest>`. DICOM network protocol ---------------------- This concludes our overview of the DICOM file format. :ref:`As written above <dicom-format>`, we now describe the second main part of the DICOM standard, i.e. the **DICOM network protocol**. .. _dicom-protocol-overview: Overview ^^^^^^^^ The DICOM protocol is actually one of the earliest example of `Web services <https://en.wikipedia.org/wiki/Web_service>`__, long before the introduction of `SOAP <https://en.wikipedia.org/wiki/SOAP>`__ or `REST <https://en.wikipedia.org/wiki/Representational_state_transfer>`__. It allows to: 1. **Test the connection** between two devices (:ref:`C-Echo <dicom-echo>`). 2. **Send images** from the local imaging device to a remote device (:ref:`C-Store <dicom-store>`). 3. **Search the content** of a remote device (:ref:`C-Find <dicom-find>`). 4. **Retrieve images** from a remote device (:ref:`C-Move <dicom-move>`). Here is a picture that summarizes some key concepts: .. image:: images/Protocol.svg :height: 200px :align: center In the DICOM terminology, the client of a DICOM service is called a **service class user** (SCU), and the server that handles the requests is called a **service class provider** (SCP). The client sends a request that is encoded as a DICOM file (the **command**), and the server answers with a DICOM file. The connection of a DICOM client to a DICOM server is called an **association**. Such an association starts with a handshake where the client and the server agree on which commands can be exchanged between them, and on which :ref:`transfer syntaxes <dicom-pixel-data>` are supported. The result of this negotiation is called the **presentation context**. Once the association is negotiated, this communication channel can be used to successively send multiple, independent commands. Parameters of a DICOM server ^^^^^^^^^^^^^^^^^^^^^^^^^^^^ Historically, the DICOM protocol was designed to work over `point-to-point links <https://en.wikipedia.org/wiki/Point-to-point_(telecommunications)>`__. Nowadays, the DICOM protocol is used over the `TCP/IP stack <https://en.wikipedia.org/wiki/Internet_protocol_suite>`__. This implies that a DICOM server can be identified by specifying the parameters of its `network socket <https://en.wikipedia.org/wiki/Network_socket>`__: 1. Its **IP address** (or, equivalently, its symbolic DNS hostname). 2. Its **TCP port** (the standard DICOM port is 104, but Orthanc uses the non-priviliged port 4242 by default). Furthermore, each imaging device (may it be a client or a server) must be associated with a symbolic name that is called the **application entity title (AET)**. The AET is assumed to be unique inside the Intranet of the hospital. For best compatibility between vendors, the AET should be only made of alphanumeric characters in upper case (plus the "``-``" and "``_``" characters), and its length must be below 16 characters. Taken together, the IP address, the TCP port and the AET describe all the parameters of a DICOM server. The administrators of a medical imaging network should carefully keep track of these parameters for each imaging device, and should define an hospital-wide policy to assign AETs to new devices. Configuring Orthanc ^^^^^^^^^^^^^^^^^^^ Orthanc can act both as a DICOM client and as a DICOM server, depending on the parameters in its :ref:`configuration file <configuration>`. To configure the **DICOM server** of Orthanc, the following options are especially important: 1. ``DicomServerEnabled`` must be set to ``true``. 2. ``DicomAet`` must be set to the AET that is reserved to Orthanc. 3. ``DicomPort`` specifies the TCP port of the DICOM server. To configure Orthanc as a **DICOM client**, you must list the remote DICOM servers that are known to Orthanc into the ``DicomModalities`` option. For each remote server, you must specify in the following order: 1. An user-friendly, symbolic name for the server that will be displayed by :ref:`Orthanc Explorer <orthanc-explorer>` (possibly its AET). 2. The AET of the remote server. 3. Its IP address or its hostname. 4. Its DICOM port (most probably 104, or 4242 if the remote server is another instance of Orthanc). Of course, after any change to the configuration of Orthanc, the software must be restarted to take the new parameters into account. .. _dicom-echo: C-Echo: Testing connectivity ^^^^^^^^^^^^^^^^^^^^^^^^^^^^ Routers might block the DICOM protocol between separate `subnets <https://en.wikipedia.org/wiki/Subnetwork>`__ (often, only the HTTP, HTTPS and SSH protocols are enabled by default). Furthermore, the firewalls that are installed on the clients or on the servers might also block the DICOM protocol. This is especially true for the `Microsoft Windows firewall <https://en.wikipedia.org/wiki/Windows_Firewall>`__ and for :ref:`RedHat-based Linux boxes <redhat>`. As a consequence, after any change in the DICOM topology of an hospital (notably when connecting two imaging devices), one should always check whether the DICOM protocol can travel from end to end, i.e. between the DICOM client and the DICOM server. This is where the **DICOM Echo service** comes into play. This service is triggered when the client sends a so-called ``C-Echo`` command to the server as its DICOM query. The server answers with an empty DICOM answer. In practice, to test the connectivity between two devices, you should: 1. Use the standard command-line tool ``ping`` to test the **TCP-level connectivity** between the client and the server, then 2. Issue the **C-Echo** from the client to the server to test the DICOM-level connectivity. The second step can be done directly from :ref:`Orthanc Explorer <orthanc-explorer>`, the embedded administrative interface of Orthanc, in the "*Query/Retrieve*" panel, as depicted below: .. image:: images/Echo.png :align: center :width: 450px | In this screenshot, ``sample`` corresponds to the symbolic name of a DICOM server that is declared in the ``DicomModalities`` :ref:`configuration option <configuration>`. Once DICOM Echo succeeds, the client should be able to send images to the server, and to initiate a query/retrieve. This is the topic of the following sections. .. _dicom-store: C-Store: Sending images to a server ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The **DICOM Store Service** is used to send DICOM instances to a remote imaging device. This service is triggered when the client sends to the server a so-called ``C-Store`` command together with the content of a DICOM instance. Schematically, C-Store works as follows: .. image:: images/CStore.svg :align: center :width: 500px Orthanc can act both as a C-Store client (SCU) or as a C-Store server (SCP). In other words, it can either send or receive DICOM files. In the :ref:`Orthanc Explorer <orthanc-explorer>` interface, each DICOM resource (patient, study, series or instance) comes with a button entitled "*Send to remote modality*". Clicking on this button allows to send the image to any DICOM server that is declared in the ``DicomModalities`` :ref:`configuration option <configuration>`. In the following screenshot, all the instances of one patient will be sent to the device whose symbolic name is ``sample``: .. image:: images/CStoreGui.png :align: center :width: 450px .. _dicom-find: C-Find: Browsing the content of a server ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The **DICOM Find Service** is used to **search** a list of DICOM resources that are hosted by some remote DICOM server. The kind of resource that is looked for (patients, studies or series) must be specified, leading to the **query level** of the query. Besides the query level, the query contains a set of filters on DICOM tags of interest: These filters are essentially `wildcards <https://en.wikipedia.org/wiki/Glob_(programming)>`__ describing the resources that are looked for. This service is triggered when the client sends to the server a so-called ``C-Find`` command that encodes the query level and the filters. Schematically, C-Find works as follows: .. image:: images/CFind.svg :align: center :width: 500px Orthanc can act both as a C-Find client (SCU) or as a C-Find server (SCP). In other words, it can be used to search the content of a remote server, and conversely it can inform a remote client about its own content. In the :ref:`Orthanc Explorer <orthanc-explorer>` interface, it is possible to initiate a search at the study level. This feature is available in the "*Query/Retrieve*" panel, as depicted below: .. image:: images/CFindGui1.png :align: center :width: 500px | This screenshot shows that we are looking for a study whose associated patient has a name that starts with "*Brain*", and that is of MR modality. Orthanc Explorer then lists the matching studies: .. image:: images/CFindGui2.png :align: center :width: 500px | It is then possible to click on some matching study, to list the individual series it is made of: .. image:: images/CFindGui3.png :align: center :width: 500px .. _dicom-move: C-Move: Query/retrieve ^^^^^^^^^^^^^^^^^^^^^^ This brings us to the last important component of the DICOM network protocol, the **DICOM Move Service**. This service is notably used to locally retrieve DICOM files from a remote server, given the results of a :ref:`C-Find query <dicom-find>`. Taken together, ``C-Find`` and ``C-Move`` give rise to the **query/retrieve** mechanism at is at the core of the exchange of DICOM files within the hospital. C-Move is probably the part of the DICOM standard that is the less intuitive, which leads to many configuration problems in medical imaging networks. This stems from the fact that C-Move is actually not limited to query/retrieve. It is a more generic protocol that can involve up to **3 distinct imaging devices**, as depicted below: .. image:: images/CMove.svg :align: center :width: 500px Whenever an imaging device (called the *issuer* above) initiates a C-Move command, it asks a DICOM server (called the *source* above) to send some of its images to another DICOM server (called the *target* above). Accordingly, a C-Move command encodes the :ref:`identifiers <dicom-identifiers>` of the DICOM resources to be sent, together with the AET of the target server. To put it in other words, a C-Move command drives a **C-Store between two remote DICOM servers** (the *source* and the *target*). The query/retrieve mechanism corresponds to the special case of a C-Move command where the target and the issuer are the same imaging device. The most common configuration problem for query/retrieve is therefore to forget to declare the AET of the "*issuer/target*" device into the configuration of the "*source*" device. Orthanc can act both as a C-Move client (SCU) or as a C-Move server (SCP). This implies that Orthanc can either initiate a query/retrieve, or be driven as part of a query/retrieve request. You might want to give a look at the ":ref:`query-retrieve`" section of this book to learn how to concretely configure Orthanc for query/retrieve. A C-Move session can be initiated from the :ref:`Orthanc Explorer <orthanc-explorer>` interface, after a :ref:`C-Find query <dicom-find>` is complete. It is sufficient to click on the download button that is to the right of the study or series of interest: .. image:: images/CMoveGui1.png :align: center :width: 500px | A dialog box then pops up, asking the AET of the *target* modality. By default, this field is pre-filled with the AET of Orthanc, which corresponds to the initiation of a query/retrieve: .. image:: images/CMoveGui2.png :align: center :width: 500px | *Note 1:* Even if C-Move may seem counter-intuitive, it is the only way to initiate a query/retrieve. Once upon a time, there was a conceptually simpler ``C-Get`` command, but this command is now deprecated. *Note 2:* As :ref:`written above <dicom-pixel-data>`, the Orthanc engine is quite generic and is compatible with virtually any image compression algorithm (aka. transfer syntax). In particular, during the :ref:`negotiation of a presentation context <dicom-protocol-overview>`, Orthanc reports by default that it is compatible with the JPEG 2000 encoding. This leads some PACS engines to compress their images before sending them to Orthanc, so as to reduce the network bandwidth. Unfortunately, because many medical image analysis software are not compatible with such an image compression, the JPEG 2000 image that is received by Orthanc might be unusable by such software. You might therefore have to **disable transfer syntaxes** by setting the ``*TransferSyntaxAccepted`` options to ``false`` in the :ref:`configuration file of Orthanc <configuration>` (by default, all the transfer syntaxes are enabled). Using HTTP instead of the DICOM protocol ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ We conclude this brief overview of DICOM by insisting on the fact that the **DICOM protocol inherently targets the Intranet** of a single hospital, not the Internet or the cloud. This protocol might be blocked by outbound firewalls, and there is no convention ensuring that the AETs are globally unique across all the hospitals. Furthermore, even though the DICOM protocol supports TLS encryption, this feature is rarely enabled. Depending on your application, you might therefore want to leverage the **HTTP protocol** in the context of DICOM. Such Web-based protocols are probably more familiar to physicians/physicists/software engineers, are easier to work with, can be transparently encrypted (**HTTPS**), and are compatible with multiple-hospital scenarios. To this end, you have two possibilities: 1. Resort to the :ref:`Orthanc peer <peers>` mechanism. Because each Orthanc server comes with its built-in :ref:`REST API <rest>`, remote systems can obtain a full programmatic control over the content of Orthanc. This access can be secured by HTTP authentication and :ref:`SSL encryption <https>`. The :ref:`Orthanc Explorer <orthanc-explorer>` interface can transparently use this peer mechanism to send DICOM files over HTTP(S). 2. Resort to the `DICOMweb standard <http://www.dicomweb.org/>`__, that is an extension to the DICOM standard specifying how to access the content of a remote DICOM server through HTTP(S). Because the peer mechanism is bound to Orthanc, DICOMweb offers a less expressive, but more generic access to remote servers. Importantly, a `DICOMweb plugin to Orthanc <http://www.orthanc-server.com/static.php?page=dicomweb>`__ is freely available.