parents | |
children | 8f3f79aeb8cc |
comparison
equal
deleted
inserted
replaced
-1:000000000000 | 0:901e8961f46e |
---|---|
1 .. _query-retrieve: | |
2 | |
3 Configuring DICOM Query/Retrieve | |
4 ================================ | |
5 | |
6 Starting with release 0.7.0, Orthanc supports DICOM Query/Retrieve | |
7 (i.e. Orthanc can act as C-Find SCP and C-Move SCP). To configure this | |
8 feature, follow these instructions: | |
9 | |
10 * Get the AET (Application Entity Title), the IP address and the port | |
11 number of your DICOM client. | |
12 * Add an entry in the ``DicomModalities`` section of your Orthanc | |
13 :ref:`configuration file <configuration>` to reflect these settings. | |
14 * Restart Orthanc with the updated configuration file. | |
15 * Symmetrically, in your DICOM client, configure an additional DICOM | |
16 node corresponding to your Orthanc AET (see the ``DicomAet`` | |
17 parameter of your Orthanc configuration, by default, ORTHANC), IP | |
18 address et port number (cf. ``DicomPort``, by default 4242). | |
19 | |
20 If you encounter configuration problem with query/retrieve, please be | |
21 sure to read the :ref:`dicom-move` section. | |
22 | |
23 | |
24 .. _ginkgo-cadx: | |
25 | |
26 Illustration: Ginkgo CADx | |
27 ------------------------- | |
28 | |
29 This section explains how to connect the `Ginkgo CADx viewer | |
30 <http://ginkgo-cadx.com/en/>`__ to an Orthanc server, both running on | |
31 the local computer. First, start Orthanc without specifying a | |
32 configuration file (i.e. using its default configuration). Then, open | |
33 the settings pannel of Ginkgo CADx: | |
34 | |
35 .. image:: ../images/GinkgoCADx1.png | |
36 :align: center | |
37 :width: 500px | |
38 | |
39 Write down the AET and the DICOM port of Ginkgo CADx (in this case, | |
40 respectively ``GINKGO_001`` and ``11112``). Then, create a new DICOM | |
41 node corresponding to Orthanc by clicking on the "*New...*" button, | |
42 which raises the following dialog box: | |
43 | |
44 .. image:: ../images/GinkgoCADx2.png | |
45 :align: center | |
46 :width: 400px | |
47 | |
48 .. highlight:: json | |
49 | |
50 Complete the highlighted fields with the default parameters of | |
51 Orthanc, as shown in the screenshot. Do not forget to click on the | |
52 "*Test connection*" button to make sure the :ref:`C-Echo <dicom-echo>` | |
53 succeeds. Stop Orthanc, create a new :ref:`configuration file | |
54 <configuration>`, and declare Gingko CADx in the ``DicomModalities`` | |
55 section, given the parameters you wrote down above:: | |
56 | |
57 // The list of the known DICOM modalities | |
58 "DicomModalities" : { | |
59 "ginkgo" : [ "GINKGO_001", "localhost", 11112 ] | |
60 }, | |
61 | |
62 Restart Orthanc using this newly created configuration file, and | |
63 you will be able to do query/retrieve from Gingko CADx through the | |
64 "*PACS Q/R*" menu. |