comparison Sphinx/source/faq/query-retrieve.rst @ 0:901e8961f46e

initial commit
author Sebastien Jodogne <s.jodogne@gmail.com>
date Fri, 22 Apr 2016 12:57:38 +0200
parents
children 8f3f79aeb8cc
comparison
equal deleted inserted replaced
-1:000000000000 0:901e8961f46e
1 .. _query-retrieve:
2
3 Configuring DICOM Query/Retrieve
4 ================================
5
6 Starting with release 0.7.0, Orthanc supports DICOM Query/Retrieve
7 (i.e. Orthanc can act as C-Find SCP and C-Move SCP). To configure this
8 feature, follow these instructions:
9
10 * Get the AET (Application Entity Title), the IP address and the port
11 number of your DICOM client.
12 * Add an entry in the ``DicomModalities`` section of your Orthanc
13 :ref:`configuration file <configuration>` to reflect these settings.
14 * Restart Orthanc with the updated configuration file.
15 * Symmetrically, in your DICOM client, configure an additional DICOM
16 node corresponding to your Orthanc AET (see the ``DicomAet``
17 parameter of your Orthanc configuration, by default, ORTHANC), IP
18 address et port number (cf. ``DicomPort``, by default 4242).
19
20 If you encounter configuration problem with query/retrieve, please be
21 sure to read the :ref:`dicom-move` section.
22
23
24 .. _ginkgo-cadx:
25
26 Illustration: Ginkgo CADx
27 -------------------------
28
29 This section explains how to connect the `Ginkgo CADx viewer
30 <http://ginkgo-cadx.com/en/>`__ to an Orthanc server, both running on
31 the local computer. First, start Orthanc without specifying a
32 configuration file (i.e. using its default configuration). Then, open
33 the settings pannel of Ginkgo CADx:
34
35 .. image:: ../images/GinkgoCADx1.png
36 :align: center
37 :width: 500px
38
39 Write down the AET and the DICOM port of Ginkgo CADx (in this case,
40 respectively ``GINKGO_001`` and ``11112``). Then, create a new DICOM
41 node corresponding to Orthanc by clicking on the "*New...*" button,
42 which raises the following dialog box:
43
44 .. image:: ../images/GinkgoCADx2.png
45 :align: center
46 :width: 400px
47
48 .. highlight:: json
49
50 Complete the highlighted fields with the default parameters of
51 Orthanc, as shown in the screenshot. Do not forget to click on the
52 "*Test connection*" button to make sure the :ref:`C-Echo <dicom-echo>`
53 succeeds. Stop Orthanc, create a new :ref:`configuration file
54 <configuration>`, and declare Gingko CADx in the ``DicomModalities``
55 section, given the parameters you wrote down above::
56
57 // The list of the known DICOM modalities
58 "DicomModalities" : {
59 "ginkgo" : [ "GINKGO_001", "localhost", 11112 ]
60 },
61
62 Restart Orthanc using this newly created configuration file, and
63 you will be able to do query/retrieve from Gingko CADx through the
64 "*PACS Q/R*" menu.